Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chemosphere ; 289: 133154, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34871609

RESUMO

Among the polycyclic aromatic hydrocarbons (PAH), benzo[a]pyrene (B[a]P) has been considered more relevant than other species when estimating the potential exposure-related health effects and has been recognized as a marker of carcinogenic potency of air pollutant mixture. The current understanding of the factors which govern non-linear behavior of B[a]P and associated pollutants and environmental processes is insufficient and further research has to rely on the advanced analytical approach which averts the assumptions and avoids simplifications required by linear modeling methods. For the purpose of this study, we employed eXtreme Gradient Boosting (XGBoost), SHapley Additive exPlanations (SHAP) attribution method, and SHAP value fuzzy clustering to investigate the concentrations of inorganic gaseous pollutants, radon, PM2.5 and particle constituents including trace metals, ions, 16 US EPA priority PM2.5-bound PAHs and 31 meteorological variables, as key factors which shape indoor and outdoor PM2.5-bound B[a]P distribution in a university building located in the urban area of Belgrade (Serbia). According to the results, the indoor and outdoor B[a]P levels were shown to be highly correlated and mostly influenced by the concentrations of Chry, B[b]F, CO, B[a]A, I[cd]P, B[k]F, Flt, D[ah]A, Pyr, B[ghi]P, Cr, As, and PM2.5 in both indoor and outdoor environments. Besides, high B[a]P concentration events were recorded during the periods of low ambient temperature (<12 °C), unstable weather conditions with precipitation and increased soil humidity.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Benzo(a)pireno/análise , Monitoramento Ambiental , Humanos , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise
2.
Environ Res ; 193: 110520, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33259787

RESUMO

The previous research, aimed at exploring the relationships between the indoor and outdoor air quality, has evidenced that outdoor PM2.5-bound polycyclic aromatic hydrocarbons (PAH) levels exhibit significant daily and seasonal variations which does not necessary corresponds with PAH indoor dynamics. For the purpose of this study, a three-month measurement campaign was performed simultaneously at indoor and outdoor sampling sites of a university building in an urban area of Belgrade (Serbia), during which the concentrations of O3, CO, SO2, NOx, radon, PM2.5 and particle constituents including trace metals (As, Cd, Cr, Mn, Ni and Pb), ions (Cl-, Na+, Mg2+, Ca2+, K+, NO3-, SO42- and NH4+) and 16 US EPA priority PAHs were determined. Additionally, the analysis included 31 meteorological parameters, out of which 24 were obtained from Global Data Assimilation System (GDAS1) database. The Unmix and PAH diagnostic ratios analysis resolved the source profiles for both indoor and outdoor environment, which are comparable in terms of their apportionments and pollutant shares, although it should be emphasized that ratio-implied solutions should be taken with caution since these values do not reflect emission sources only. The highest contributions to air quality were attributed to sources identified as coal combustion and related pyrogenic processes. Noticeable correlations were observed between 5- and 6-ring high molecular weight PAHs, but, except for CO, no significant linear dependencies with other investigated variables were identified. The PAH level predictions in the indoor and outdoor environment was performed by using machine learning XGBoost method.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Humanos , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Sérvia
3.
J Radiol Prot ; 40(2): N22-N30, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32040947

RESUMO

The first step in every systematic approach to investigating population exposure to radon on a national level is to perform a comprehensive indoor radon survey. Based on general knowledge of the radon levels in Serbia and corresponding doses, the results obtained from a national indoor radon survey would allow policymakers to decide whether it is necessary to establish a national radon programme. For this reason, Serbia initiated work on a national radon action plan (RAP) in 2014 when it was decided to carry out the first national indoor radon survey. The responsibility for establishing the RAP in Serbia is that of the national regulatory body in the field of radiation protection-the Serbian Radiation and Nuclear Safety and Security Directorate (SRBATOM), formerly known as the Serbian Radiation Protection and Nuclear Safety Agency. The first national indoor radon survey was supported by the International Atomic Energy Agency (IAEA) through a Technical Cooperation Programme. Thanks to the IAEA, we received 6000 passive radon devices based on track-etched detectors. In addition, in order to ensure technical support for the project, SRBATOM formed a task force made up of expert radon representatives from national research institutions. This paper presents a thorough description of the sampling design of the first Serbian indoor radon survey. It also presents the results of the national indoor radon survey, including descriptive statistics and testing of the distribution of the obtained results for log-normality. Based on GPS coordinates, indoor radon data were projected onto a map of 10 km × 10 km grid cells. Two values were calculated for each cell to create two distinct maps. One map shows the arithmetic mean value of indoor radon concentration per grid cell, and the other map shows the number of radon detectors per grid cell used for the calculation of mean values.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Habitação , Radônio/análise , Humanos , Sérvia
4.
Radiat Prot Dosimetry ; 162(1-2): 148-51, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25080439

RESUMO

The results of analysis using correlative and multivariate methods, as developed for data analysis in high-energy physics and implemented in the Toolkit for Multivariate Analysis software package, of the relations of the variation of increased radon concentration with climate variables in shallow underground laboratory is presented. Multivariate regression analysis identified a number of multivariate methods which can give a good evaluation of increased radon concentrations based on climate variables. The use of the multivariate regression methods will enable the investigation of the relations of specific climate variable with increased radon concentrations by analysis of regression methods resulting in 'mapped' underlying functional behaviour of radon concentrations depending on a wide spectrum of climate variables.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Análise Multivariada , Exposição Ocupacional/análise , Monitoramento de Radiação , Radônio/análise , Humanos , Laboratórios , Análise de Regressão , Ventilação
5.
Appl Radiat Isot ; 87: 70-2, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24365469

RESUMO

During the last three years we investigated the variations of background simultaneously in two laboratories, the ground level (GLL) and the underground laboratory. The Forbush-like effect from March 2010 was observed in the GLL using a Ge detector and plastic veto scintillator. The underground plastic scintillator saw the same effect but the coincident veto spectrum did not detect the decrease of cosmic-ray intensity. Using a time series analysis of prominent post-radon lines, a significant radon daily variability was detected in the Ge detector background spectrum, but only in the GLL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...